氣體增壓泵安裝:安裝過程中,要避免雜物進入出口,保持出口清潔。
Gas booster pump installation: the installation process, to avoid the debris into the export, maintain export clean.
驅動氣體:請使用清潔的氣源,以保證泵能持續穩定的工作,驅動氣體要求顆粒<5um,建議在泵的驅動口加配二連體,泵在裝配時,所有運動部分已經抹有適量潤滑油,一般不再需要潤滑,如長期使用干燥的壓縮氣體驅動,建議在二連體的油杯內加入適量的潤滑油,進行油霧潤滑。氣體增壓泵:http://www.jujiaso.cn/
The driving gas: please use the clean air supply, to ensure the pump can work steadily, driven gas particle <5um, suggested in the driving export pump with two conjoined, pump in the assembly, all moving parts have been smeared with the amount of lubricating oil, no longer need to lubricate, such as long period use dry compressed air driven suggestion, adding the right amount of oil in the oil cup two conjoined, oil mist lubrication.
連接管路:根據泵的輸出壓力,請選擇合適的出口連接管路,確保承受泵的最大輸出壓力。
Connection line: according to the output pressure of the pump, please select the appropriate outlet connecting pipe, to ensure maximum output pressure pump.
入口壓力:入口壓力越大,流量也隨之增大,單級增壓泵,需要一定的預壓才能達到理論最大輸出壓力。雙級增壓泵,入口壓力要求1-10bar,入口壓力不允許超過10bar,建議<7bar。確保泵的使用壽命。
Entrance: the entrance pressure more pressure, flow rate increases, the single-stage booster pump, need some preload can achieve the maximum output pressure theory. Double stage booster pump, entrance pressure 1-10bar, entrance pressure does not exceed 10bar
氣體增壓泵啟動:該泵的最小驅動壓力為1.5-2bar,可通過調整二連體調壓閥調節驅動氣體的壓力,以達到你所需要的壓力。
在泵的氣驅部分該系列需用潤滑型氣體,以便讓密封和其他內部零件得到潤滑,該系列泵的驅動活塞直徑為160mm 氣驅氣體增壓系統設備應用范圍:
氣體增壓泵管件,軟管,閥門,壓力容器,汽缸等提供靜態和爆破測試航空航天附件維修后的靜態、動態測試安全閥門校定閥門及井口裝置水中冒泡試驗氣壓調節器的檢測汽車制動系統測試可以增壓氫氣、氧氣、氮氣、氦氣、空氣、天然氣等大部分氣體。
相關閱讀:氣體增壓系統在生活中的應用